<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>16020</ErrorNumber>
<ErrorFamily>Image</ErrorFamily>
<ErrorMessage>
IMAGE: DAOM calibration appears inaccurate!
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Green</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware was unable to calibrate the stroke to the tolerance specified by the "set media &lt;media&gt; stol"
parameter.  The tolerance was increased automatically, possibly up to the limit specified by the "set media
&lt;media&gt; ltol" parameter.
</text></DescriptionText>
<DescriptionText><text>
A DAOM calibration should be performed.  If this does not help the problem, and the desired exposure
level is reasonable, this message can indicate a failing head.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Report this message to Creo Service.  If no other errors are reported, the platesetter will continue working
fine, but may need servicing soon.
</text></DescriptionText>
</OperatorAction>
<Cause>
Exposure level too high
</Cause>
<Cause>
Head is failing.
</Cause>
<Cause>
DAOM calibration is inaccurate
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/media_cal_stol.xml</LinkAddress><LinkTitle>NVS: media stol</LinkTitle></Link>
<Link><LinkAddress>../nvs/media_cal_ltol.xml</LinkAddress><LinkTitle>NVS: media ltol</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:28 2008 PST
</Updated>
<Links>
</Links>
</Error>